Signal Booster III Specific Alarms

Follow

A trap is sent whenever the condition changes.  The possible conditions are:

 

Alarm Sent What It Means What to do about it
DAC Overflow The output level to the booster is too high Reduce output power.
ADC Overflow The input level of the booster is too high Reduce AGC reference level.
Down Converter LO Not Locked There is an issue with the 10 MHz clock In the system tab, make sure that the Use External Oscillator is set to correct value.  If using an external oscillator, make sure that it is providing 10MHz.  If not using external oscillator call support
Up Converter LO Not Locked There is an issue with the 10 MHz clock In the system tab, make sure that the Use External Oscillator is set to correct value.  If using an external oscillator, make sure that it is providing 10MHz.  If not using external oscillator call support

Signal Booster III General Alarms 

A trap is sent whenever the condition changes.  The possible conditions are:

 

Condition What it means What to do
Normal Self Explanatory This is good.
Power Amp Over Current Self Explanatory Call support
Power Amp Over Temperature Self Explanatory Make sure heat sink is getting airflow.  Call Support
Module Over Current Self Explanatory Call Support
Module Over Temperature Self Explanatory Make sure heat sink is getting air flow. Call Support
ADC Overflow Same as ADC Overflow Alarm Same as the alarm
DAC Overflow Same as DAC Overflow Alarm Same as the alarm
LO Not Locked Combination of Up Converter and Down Converter Not Locked Alarms Same As the Alarm
     
Oscillation has Occurred There could be a lack of Isolation, Bad load on the output of the booster or an internal error Check Antenna Isolation and Gain setting in booster. Call Support
Input Overload Internal Error Call Support
SPI Flash Read ID Internal Error Call Support
SPI Flash Read Internal Error Call Support
Channel Module Flash Read Error Internal Error Call Support
Channel Module Flash Unlock Error Internal Error Call Support
Channel Module Flash Erase Error Internal Error Call Support
Channel Module Flash Program Error Internal Error Call Support
Filter Restore Read Error Internal Error Call Support
Filter Restore Init Error Internal Error Call Support
Filter Backup Fault Internal Error Call Support
Monitor Read Fault Internal Error Call Support
Status ADC Control Fault Internal Error Call Support
Status ADC Read Fault Internal Error Call Support
Over range Setup Fault Internal Error Call Support
Over range Control Fault Internal Error Call Support
Over range Read Fault Internal Error Call Support
Test Signal Off Fault The test signal was turned off. No issue. Status Info
Test Signal On Fault The test signal is on for at least one of the channels or internal error If not desired turn the test signal off and filter or wait ten minutes and it will turn off itself.
Channel Module Register Write Fault Internal Error Call Support

 